Plumbing Installed For Water Free Urinals

  1. Plumbing Installed For Water Free Urinals Pictures
  2. Plumbing Installed For Water Free Urinals For Sale

Re: Urinal rough in. Author: Deb (ID) No, each urinal will most likely need its own vent. In some places you may be able to use a double fixture fitting and vent 2 off the double fitting. You cannot, however, simply put 1 vent at the end of the last fixture. You come out horizontally and connect to a 2x1-1/2x2 san tee.

A Smarti water-free conversion kit. A maximum of x4 HP Key-Valves™ per urinal per year. Smarti Steri Kleen Spray – to spray the bowl and pipe-work once a day. Smarti Steri Kleer Pipe Pods – to place in the pipe work to keep the pipes clear and odour-free. A new urinal if required. Flushometer toilets & urinals & waterless urinals: This article describes flushometer type valve operated toilets and urinals and also waterless urinal operation that use no flush valve and no water. The flushometer valve, operated by building water pressure, eliminates the requirement for a cistern or flush tank to operate the toilet or urinal. A number of Waterless Urinals and Reduced Flushing Systems do not functionally overcome common urinal problems such as odours, blockages and general poor hygiene. This being due to the technology utilized, the way in which they were installed and the maintenance practices adopted thereafter. Each water closet, urinal, clinical sink and any plumbing fixture that depends on trap siphonage to discharge the fixture contents to the drainage system shall be provided with a flushometer valve, flushometer tank or a flush tank designed and installed to supply water in quantity and rate of flow to flush the contents of the fixture, cleanse.

Edward's Enterprises offers both toilet & urinal installations & repairs including:

Free
  • American Standard toilet clogs cleared

  • Zurn Flushometer installations

  • Motion sensor flushometers rebuilt

  • Waterless urinal cartridges swapped out

  • Toilet flappers fixed

  • Brasscraft supply lines installed

  • Toilet wall valves repaired

  • Bemis toilet seats replaced

  • Urinal water flow adjusted

  • Leaky toilet tank fixed

  • 2 piece Kohler toilets installed

  • 1 piece American Standard toilet installations

  • Toto urinals replaced

  • Wax ring & closet flange installs

  • Universal toilet handle repairs

  • Sloan pressure tank installs

  • Fluidmaster flush valves replaced

  • Toilet tank floats repaired

Our many years in the home & commercial repair & handyman service improvement trade give us the perspective & know-how critical to carrying out projects of any size; from a simple toilet supply line repair to resetting a leaky urinal & replacing the whole toilet plumbing, bowl & tank.
Need to find out if we can help with your bathroom toilet replacement? Call our office to discuss your new ADA height toilet installation plans!

INSTALLATION

The following information relates to the installation of Waterless urinals in new installation and retrofit situations. Most US Plumbing Codes require urinals to be installed so that the non-ADA urinal lip to floor height is 24' (610 mm), and for ADA* installations 17' (430 mm) urinal lip to floor.

Waterless urinals install like any conventional urinal fixture. Each urinal comes with the necessary hardware plus two EcoTraps®. In most retrofit situations, you can use the existing flange from the conventional urinal to install the touch-free urinal. Saves time!

Approximate installation times are:

  • Retrofit, simple change-out : 45 - 60 minutes

  • Retrofit, lower rough-in : 90 -120 minutes**

  • New Installation, with appropriate rough-in height: 15-25 minutes

Times are approximate and may vary according to present plumbing construction and materials.

**The additional cost to lower a rough-in may be in most cases 1 hour by a plumbing professional. This additional cost will usually just add a couple of months to your already short payback period.

NON-ADA URINALS

To determine the correct rough-in (drain line) height for non-ADA urinals, measure the distance on your current flushed urinal from the bottom of the screws on the urinal to the restroom floor. This is your current rough-in height (A). Then consult the urinal specification sheet of your Waterless urinal of choice to install. Look for the distance measurement between the urinal outlet and lip. (B).

/avg-free-error-installing/. Add A+B to come up with the lip to floor height the Waterless urinal will give you.

Example 1: (A) is 15” (381 mm), (B) is 9”(229 mm) = 24”(610 mm) lip to floor. Simple exchange of urinal.

Example 2: (A) is 18”(457 mm), (B) is 9”(229 mm) = 27” (686 mm) lip to floor. Lower rough-in height by 3”(76 mm) to come to 24”(610 mm) total.

ADA URINALS

To determine the correct rough-in (drain line) height for ADA urinals, measure the distance on your current flushed urinal from the bottom of the screws on the urinal to the restroom floor. This is your current rough-in height (A). Then consult the urinal specification sheet of your Waterless urinal of choice to install. Look for the distance measurement between the urinal outlet and lip. (B).

Plumbing Installed For Water Free Urinals Pictures

Add A+B to come up with the lip to floor height the Waterless urinal will give you.

Example 1: (A) is 8'(203 mm), (B) is 9”(229 mm) = 17”(430 mm) lip to floor. Simple exchange of urinal.

Example 2: (A) is 12”(305 mm), (B) is 9”(229 mm) = 21”(533 mm) lip to floor. Lower rough-in height by 3”(76 mm) to come to 17”(430 mm) total.

Plumbing Installed For Water Free Urinals For Sale

* ADA is a uniquely U.S. requirement. Consult your local/national plumbing codes for required installation heights.